Difference between revisions of "DELL flashing LED on a disk"
⧼vector-jumptonavigation⧽
⧼vector-jumptosearch⧽
Line 1: | Line 1: | ||
+ | <span data-link_translate_nl_title="DELL knipperende LED op een schijf" data-link_translate_nl_url="DELL knipperende LED op een schijf"></span>[[:nl:DELL knipperende LED op een schijf]][[nl:DELL knipperende LED op een schijf]] | ||
<span data-link_translate_it_title="DELL LED lampeggiante su un disco" data-link_translate_it_url="DELL LED lampeggiante su un disco"></span>[[:it:DELL LED lampeggiante su un disco]][[it:DELL LED lampeggiante su un disco]] | <span data-link_translate_it_title="DELL LED lampeggiante su un disco" data-link_translate_it_url="DELL LED lampeggiante su un disco"></span>[[:it:DELL LED lampeggiante su un disco]][[it:DELL LED lampeggiante su un disco]] | ||
<span data-link_translate_pt_title="DELL LED intermitente num disco" data-link_translate_pt_url="DELL LED intermitente num disco"></span>[[:pt:DELL LED intermitente num disco]][[pt:DELL LED intermitente num disco]] | <span data-link_translate_pt_title="DELL LED intermitente num disco" data-link_translate_pt_url="DELL LED intermitente num disco"></span>[[:pt:DELL LED intermitente num disco]][[pt:DELL LED intermitente num disco]] |
Revision as of 14:32, 29 July 2021
nl:DELL knipperende LED op een schijf
it:DELL LED lampeggiante su un disco
pt:DELL LED intermitente num disco
es:LED parpadeante de DELL en un disco
fr:DELL faire clignoter la LED d'un disque
This article has been created by an automatic translation software. You can view the article source here.
Introduction
We will see how to flash the LED of a disk with DELL omconfig, this can be useful to tell the media which disk to change.
Course
We have isolated the faulty disk, which is located on :
Controller ID : 0
Disk ID: 0:0:2
We are going to make the LED of the latter flash in order to find it more easily physically:
$ omconfig storage pdisk action=blink controller=0 pdisk=0:0:2 Command successful!
And to stop the flashing :
$ omconfig storage pdisk action=unblink controller=0 pdisk=0:0:2 Command successful!